Document Type : Original Research Article
Authors
1
Department of Gynecologic Oncology, Vali-Asr Hospital, Tehran University of Medical Sciences, Tehran, Iran
2
Department of Obstetrics and Gynecology, Faculty of Medicine, Vali-Asr Reproductive Health Research Center, Tehran University of Medical Sciences, Tehran, Iran
3
Clinical Research Development Center, Imam Reza Hospital, Kermanshah University of Medical Sciences, Kermanshah, Iran
4
Vali-E-Asr Reproductive Health Research Center, Family Health Research Institute, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
5
Department of Obstetrics and Gynecology, Yas Hospital, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
Abstract
Abstract
Background: Standardized Ovarian-Adnexal Reporting and Data System (O-RADS) ultrasound-based preoperative risk stratification of adnexal masses is essential to guide appropriate referral and surgical planning in gynecologic oncology. Validation studies are needed to assess its diagnostic performance across different clinical settings.
Methods: This retrospective study analyzed 186 women who underwent surgery for adnexal masses at Imam Khomeini Hospital Complex, Tehran University of Medical Sciences. All patients had preoperative O-RADS ultrasound (US) assessments and final histopathology. O-RADS US categories were classified as low risk (categories 2-3) or high risk (categories 4-5). Diagnostic performance for predicting malignancy (borderline or invasive tumors) versus benign lesions was calculated.
Results: Final histopathology showed 111 benign lesions (59.7%) and 75 malignant lesions (40.3%), including 30 borderline and 45 invasive tumors. Malignancy prevalence increased with O-RADS US category: 4.0% for O-RADS 2, 0% for O-RADS 3, 38.8% for O-RADS 4, and 82.8% for O-RADS 5. Using high-risk designation (O-RADS 4-5) to predict malignancy, ultrasound achieved sensitivity 98.7% (95% CI 92.8-99.8%), specificity 54.1% (44.8-63.0%), positive predictive value 59.2% (50.4-67.4%), negative predictive value 98.4% (91.3-99.7%), and accuracy 72.0% (65.2-78.0%).
Conclusion: O-RADS ultrasound demonstrates excellent sensitivity and negative predictive value for detecting malignant adnexal masses, supporting its use for preoperative risk stratification and surgical planning decisions. The high NPV in low-risk categories can guide conservative management, while high-risk ultrasound findings support appropriate referral to gynecologic oncology centers.
Keywords
Subjects