Iranian Society of Gynecology Oncology (IRSGO)

Diagnostic Accuracy of Ultrasound in Detecting Abnormal Placental Adhesions: Correlation with Surgical Pathology Findings

Document Type : Original Research Article

Authors

1 Assistant Professor of Gynecology Oncology, Department of Obstetrics and Gynecology, School of Medicine, Nekouei-Hedayati-Forghani Hospital, Qom University of Medical Sciences

2 Assistant Professor of Vascular Surgery Department of Surgery, School of Medicine Qom University of Medical Sciences

3 Assistant Professor of Radiology School of Medicine Qom University of Medical Sciences

4 Assistant Professor of Radiology, School of Medicine, Alborz University of Medical Sciences

5 Assistant Professor of Radiology Shahid Beheshti University of Medical Sciences

6 School of Medicine, Qom University of Medical Sciences

7 Radiology Resident, Department of Radiology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran

Abstract
Background: Abnormal placental adhesion, also known as Placenta Accreta Spectrum (PAS), is a high-risk obstetric condition characterized by pathological attachment of the placenta to the uterine wall. Early and accurate diagnosis is crucial to reducing maternal morbidity and mortality. Ultrasound is the most commonly used non-invasive imaging modality for prenatal assessment of suspected PAS due to its safety, accessibility, and cost-effectiveness.

Materials and Methods: This prospective diagnostic accuracy study included 134 pregnant women with at least two risk factors for abnormal placental adhesion. All participants underwent a prenatal ultrasound performed by a single experienced radiologist. Ultrasound findings were considered positive for PAS if there was loss of the retroplacental clear zone or disruption of the uterine–bladder interface on color Doppler imaging. Prenatal ultrasound results were compared with intraoperative findings and postoperative pathological examination, which served as the gold standard. Diagnostic performance indices, including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy, were calculated.

Results: Pathology confirmed abnormal placental adhesion in 38 cases (28.4%), while ultrasound was positive in 49 cases (36.6%). Sensitivity and specificity of ultrasound were 63.2% and 74.0%, respectively. PPV and NPV were 49.0% and 83.5%, with an overall accuracy of 71.6%. There was a significant correlation between ultrasound findings and pathological results (P < 0.001).

Conclusion: Prenatal ultrasound demonstrates moderate diagnostic accuracy for detecting abnormal placental adhesion. While its negative predictive value is relatively high, the positive predictive value is limited, suggesting that ultrasound is useful as a screening tool